***                             SIMetrix/SIMPLIS                             ***
***                 Load Component Values configuration file                 ***
***                                created on                                ***
***                             Date : 7/18/2014                             ***
***                              Time : 15:58:45                             ***
***                                                                          ***
********************************************************************************
*** File : C:\Training\Module_3_Examples\3.1_change_vo_to_5p5V.compvalues.txt

*** !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! ***
*** Although this file was auto-generated, we have editing it for our own purposes. ***
*** !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! ***

***
*** Component with reference : V1
*** ADDRESS	VALUE
***

*** Change value to, with uniform disty.
V1.VALUE	 {310*Unif(0.0333)}

***
*** Component with reference : R6
*** ADDRESS	VALUE
***

*** Add MC tolerance, and increase nominal Vo to 5.5V
R6.VALUE	{5.7k*Gauss(0.05)}

***
*** Component with reference : R7
*** ADDRESS	VALUE
***

*** Add MC tolerance
R7.VALUE	{4.75k*Gauss(0.05)}

***
*** Component with reference : R2
*** ADDRESS	VALUE
***

R2.VALUE	1.5

***
*** Component with reference : L4
*** ADDRESS	VALUE
***

*** multiply all values by 10%
L4.VALUE	"NSEG=5 X0=-{0.50*1.1} Y0=-{1.655m*1.1*(L4_Tol)} X1=-{0.45*1.1} Y1=-{1.65m*1.1*(L4_Tol)} X2=-{0.40*1.1} Y2=-{1.6m*1.1*(L4_Tol)} X3={0.40*1.1} Y3={1.6m*1.1*(L4_Tol)} X4={0.45*1.1} Y4={1.65m*1.1*(L4_Tol)} X5={0.50*1.1} Y5={1.655m*1.1*(L4_Tol)}"